Appendix 7. EMC Installation Guidelines
A7 - 13
Example of using MX13 Series
This is a noise filter with the same dimensions as MDS-D/DH drive unit depth (200mm) and height
(380mm). This unit can be laid out easily in the device by arranging it in a row with the servo unit.
As with the servo unit, the terminals are arranged on the front enabling ideal wire lead-out.
Refer to the following usage examples for details.
Noise filter (MX13 Series)
Servo unit
200
380
Wire to 3-phase power supply
Noise filter input terminal
Noise filter output terminal
Servo input terminal
Wire from noise filter to servo
Example of noise terminal voltage attenuation
EMI data for independent control panel EMI data for control panel + noise filter
(with six-axis servo unit mounted) (MX13030)
Output derating
Noise terminal voltage
dBuV
Frequency [MHz]
Noise terminal voltage
Frequency [MHz]
[dBuV]
Current (%)
mbient temperature Ta (°C)