5. Peripheral Devices
5 - 2
5-1 Selection of wire
5-1-1 Example of wires by unit
Selected wires must be able to tolerate rated current of the unit’s terminal to which the wire is
connected.
How to calculate tolerable current of an insulated wire or cable is shown in “Tolerable current of electric
cable” (1) of Japanese Cable Makers’ Association Standard (JCS)-168-E (1995), its electric equipment
technical standards or JEAC regulates tolerable current, etc. wire.
When exporting wires, select them according to the related standards of the country or area to export.
In the UL standards, certification conditions are to use wires of 60
o
C and 75
o
C product. (UL508C)
Wire’s tolerable current is different depending on conditions such as its material, structure, ambient
temperature, etc. Check the tolerable current described in the specification of the wire to use.
Example of wire selections according to each standard is as follows.
(1) 600V vinyl insulated wire (IV wire) 60
o
C product
(Example according to IEC/EN60204-1, UL508C)
TE1
(L1, L2, L3, )
TE2
(L+, L-)
TE3
(L11, L21, L12, L22, MC1)
Terminal
name
Unit type
mm
2
AWG mm
2
AWG mm
2
AWG
MDS-C1-CV-37
3.5 12
MDS-C1-CV-55
3.5 12
MDS-C1-CV-75
5.5 10
MDS-C1-CV-110
14 6
MDS-C1-CV-150
22 4
MDS-C1-CV-185
30 3
MDS-C1-CV-220
38 2
MDS-C1-CV-260
50 -
MDS-C1-CV-300
60 -
Power supply
unit
MDS-C1-CV-370
- -
Same as TE1
1.25 to 2 16 to 14
MDS-C1-SPA-55
3.5 12
MDS-C1-SPA-75
5.5 10
MDS-C1-SPA-110
8 8
MDS-C1-SPA-150
14 6
MDS-C1-SPA-185
22 4
MDS-C1-SPA-220
30 3
MDS-C1-SPA-260
38 2
Spindle drive
unit
MDS-C1-SPA-300
60 -
Match with TE2 of
selected power supply
unit
1.25 to 2 16 to 14
(2) 600V double (heat proof) vinyl insulated wire (HIV wire) 75
o
C product
(Example according to IEC/EN60204-1, UL508C)
TE1
(L1, L2, L3, )
TE2
(L+, L-)
TE3
(L11, L21, L12, L22, MC1)
Terminal
name
Unit type
mm
2
AWG mm
2
AWG mm
2
AWG
MDS-C1-CV-37
2 14
MDS-C1-CV-55
3.5 12
MDS-C1-CV-75
5.5 10
MDS-C1-CV-110
14 6
MDS-C1-CV-150
14 6
MDS-C1-CV-185
22 4
MDS-C1-CV-220
30 3
MDS-C1-CV-260
38 2
MDS-C1-CV-300
38 2
Power supply
unit
MDS-C1-CV-370
50 -
Same as TE1
1.25 to 2 16 to 14
MDS-C1-SPA-55
2 14
MDS-C1-SPA-75
3.5 12
MDS-C1-SPA-110
5.5 10
MDS-C1-SPA-150
14 6
MDS-C1-SPA-185
14 6
MDS-C1-SPA-220
22 4
MDS-C1-SPA-260
30 3
Spindle drive
unit
MDS-C1-SPA-300
38 2
Match with TE2 of
selected power supply
unit
1.25 to 2 16 to 14