2. Specifications
2 - 23
2-3-2 Precautions for installing multiple power supply units
The methods for installing the two spindles are explained here as an example for installing multiple
power supply units.
NC(PC)
MC
NFB1(No.1)
00VAC
AC rector
(B-AL No.1)
Contactor (No.1)
C
N
10
11
12
8A
9A
C
N
4
C
N
4
L+, L-
L11, L21
MC1
MDS-C1-SPA (No.1) MDS-C1-CV (No.1)
L1, L2, L3
L+, L-
L11, L21
MC1
MDS-C1-SPA (No.2)
L1, L2, L3
MC
MDS-C1-CV (No.2)
C
N
10
11
12
8A
9A
C
N
4
C
N
4
NFB1 (No.2)
AC reactor
(B-AL No.2)
Contactor (No.2)
(1) Connecting the L+, L-, L11 and L21 link bars
Connect the L+ and L- link bars independently with C1-CV(No.1) and C1-CV(No.2) as shown above.
Make sure that both C1-CV link bars are not short-circuited when connected.
(2) Connecting and selecting NFB1, contactor and AC reactor
An NFB1, a contactor and an AC reactor must be installed independently to each power supply as
shown above. (These cannot be shared.) Note that the contactor, excluding C1-CV-370, can be
omitted.
(3) Connecting the MC1 terminal (A/B-CV)
When using the contactor, set the C1-CV rotary switch to "0", and when not using, set to "1".