5. Peripheral Devices
5 - 3
(3) 600V bridge polyethylene insulated wire (IC) 105
o
C product
(Example according to JEAC8001)
TE1
(L1, L2, L3, )
TE2
(L+, L-)
TE3
(L11, L21, L12, L22, MC1)
Terminal
name
Unit type
mm
2
AWG mm
2
AWG mm
2
AWG
MDS-C1-CV-37
2 14 2 14
MDS-C1-CV-55
2 14 3.5 12
MDS-C1-CV-75
3.5 12 3.5 12
MDS-C1-CV-110
5.5 10 14 6
MDS-C1-CV-150
8 8 14 6
MDS-C1-CV-185
14 6 22 4
MDS-C1-CV-220
14 6 22 4
MDS-C1-CV-260
22 4 30 3
MDS-C1-CV-300
38 2 38 2
Power supply
unit
MDS-C1-CV-370
38 2 50 -
1.25 to 2 16 to 14
MDS-C1-SPA-55
2 14
MDS-C1-SPA-75
3.5 12
MDS-C1-SPA-110
5.5 10
MDS-C1-SPA-150
14 6
MDS-C1-SPA-185
14 6
MDS-C1-SPA-220
22 4
MDS-C1-SPA-260
30 3
Spindle drive
unit
MDS-C1-SPA-300
38 2
Match with TE2 of
selected power supply
unit
1.25 to 2 16 to 14
CAUTION
1. Selection conditions follow IEC/EN60204-1, UL508C, JEAC8001.
Ambient temperature is maximum 40°C.
Cable installed on walls without ducts or conduits.
To use the wire under conditions other than above, check the standards you
are supposed to follow.
2. The maximum wiring length to the motor is 30m.
If the wiring distance between the drive unit and motor is 20m or longer, use a
thick wire so that the cable voltage drop is 2% or less.
3. Always wire the grounding wire.